control
   

Shear Connector Studs are designed to tie the concrete to the steel beams and to resist shear loadings between the concrete slab and steel beam in composite construction.

Length: Length is before weld. Stud when welded to base metal will be approximately 5mm shorter after weld and when welded through deck 10mm shorter after weld. Lengths for shear connector studs are generally set by governing specifications. Ask a Shearstud Ltd representative for other lengths available for specific applications. Made to order lengths are available upon request.


STANDARD SHEARSTUD RANGE IN STOCK
BS EN ISO 13918 AND BS 5400

  13mm Diameter 50mm-200mm length
  16mm Diameter 50mm-200mm length
  19mm Diameter 50mm-450mm length
  22mm Diameter 50mm-450mm length
  25mm Diameter 50mm-450mm length

TENSILE TEST BSEN 10002-1:2001

YIELD STRENGTH MIN

TENSILE STRENGTH MIN

ELONGATION MIN

SPECIFICATION

BS EN ISO 13918

350

450

15%

SPECIFICATION

BS5400 - 6

385

495

15%

SPECIFICATION BS5400 - 5
385
495
18%

Welcome | Products & Specifications | Stock | Construction | News & Events | Links | Contact Us